2015-01-31 02:52:24 | Lượt xem: 3531 | Inspection and verification
Reverification of two vertical cylindrical tanks with a stated capacity of 1,250 m³.
On 26–27 January 2015, ITVC Global carried out capacity reverification of two vertical cylindrical tanks at Military Petrochemical Joint Stock Company (MIPEC) in Hai Phong. This article records the scope of work, equipment and project photographs.
The project record references ISO 7507-3. The method described by ISO 7507-3:2006 is optical triangulation for calibrating vertical cylindrical tanks. Containing product was a condition of this particular assignment, not part of the standard’s full title.
View the original photograph in the project record. See also tank capacity calibration services.
ITVC GLOBAL · SERVICE ENQUIRIES
Share your requirements and preferred timing. ITVC will review your enquiry and discuss a suitable service scope.
Call for quotation: 0914 564 579
Ho Chi Minh City: 0859 553 986
Email: itvc.haiphong@itvc-global.com
Head office: 6th Floor, 22 Ly Tu Trong, Hong Bang Ward, Hai Phong, Vietnam.
Dịch vụ của chúng tôi
Tin tức & Sự kiện
Thư viện ảnh
Thư viện video
Copyright © 2014 ICTV. All Rights Reserved.
tư vấn iso, tu van iso, kiểm toán năng lượng, kiem toan nang luong