During carrying out the bunker survey, the inspector need to find out and collect the input parameter for bunker quantity calculation. It will decide the true quantity of bunker determined onboard the vessel.
– Tank Sounding data and Tank Capacity Table. The Corrected Sounding means below is the sounding after correcting with vessel’s trim and list.
– Temperature of Oil on Tanks,
– Oil Density @15*C,
– Table ASTM 54B (VCF) and Table ASTM 56 (WCF).
Now we could go with sample of 1 tank to test the calculation.
FO Tank No. 1 Center, Corrected Sounding = 3.27 Meter,
Temperature = 34*C,and density @ 15*C = 0.9903 (given density).
Tank Volume at Sounding 3.20 M = 157.20 Cubic Meter, at Sounding 3.30 M = 163.60 Cubic Meter.

Sample calculation tanks sounding attached below (the Temp below should be 34 C).

Note : If you do calculation with Volume in Barrel, just uses ASTM Table 6B for VCF, ASTM Table 11 for WCF in Long Ton and then ASTM Table 13 for WCF in Metric Ton.
ITVC Global is a leading provider in inspection services in Vietnam expecially in Bunker survey services. With our experience inspector, we are now carrying out the bunker survey in Hai phong, Ho Chi Minh, Da Nang, Nghi Son, Vung Tau, Phu My...
ITVC GLOBAL · SERVICE ENQUIRIES
Share your requirements and preferred timing. ITVC will review your enquiry and discuss a suitable service scope.
Hotline: 0914 564 579
Ho Chi Minh City: 0859 553 986
Email: itvc.haiphong@itvc-global.com
Head office: 6th Floor, 22 Ly Tu Trong, Hong Bang Ward, Hai Phong, Vietnam.
Dịch vụ của chúng tôi
Tin tức & Sự kiện
Thư viện ảnh
Thư viện video
Copyright © 2014 ICTV. All Rights Reserved.
tư vấn iso, tu van iso, kiểm toán năng lượng, kiem toan nang luong