2014-12-31 10:58:10 | Lượt xem: 3534 | Energy and greenhouse gases
An overview of NH₃, R12, R22, R134a, R143a and R410A, with considerations for efficiency, environmental impacts and selecting a refrigerant appropriate to the system.
A refrigerant is the working fluid in a refrigeration cycle. It absorbs heat where cooling is required and releases heat elsewhere. In a vapour-compression system, it circulates through the compressor, condenser, expansion device and evaporator.
Knowing the refrigerant in use helps a business assess performance, maintenance needs, safety and retrofit options during an energy audit.

| Refrigerant | Characteristics and considerations |
|---|---|
| NH₃ — ammonia (R717) | Used in many industrial refrigeration systems. Toxicity, leakage and material compatibility require control; design and operation must be handled by competent personnel. |
| R12 — CFC | An older refrigerant that depletes the ozone layer. When servicing legacy equipment, identify the refrigerant and follow applicable recovery and maintenance requirements. |
| R22 — HCFC | Formerly widespread in air-conditioning and refrigeration. HCFCs are subject to phase-out arrangements; check current requirements and the manufacturer’s retrofit guidance. |
| R134a — HFC | Chemical formula CF₃CH₂F. Used in refrigeration and air-conditioning applications designed for it. It does not deplete ozone but still has climate impacts. |
| R143a — HFC | A component of certain refrigerant blends. The name of an individual component does not mean it can directly replace a blend in equipment. |
| R410A — HFC blend | Used in equipment specifically designed for it. Its operating pressure is substantially higher than R22, and it is not a drop-in replacement for an R22 system. |
Ozone-depletion potential and global-warming potential are different indicators. A refrigerant that does not damage ozone can still affect the climate when released. UNEP distinguishes the HCFC phase-out from the HFC phase-down under the Montreal Protocol and Kigali Amendment.
Descriptions such as ‘non-toxic’ or ‘non-flammable’ should not be treated as absolute guarantees for every operating condition. Consult the safety data sheet, equipment documentation and installation requirements.
Do not mix or change refrigerants merely because another product costs less. Evaluate conversion options for the particular system using the technical documentation and safety requirements.
ITVC GLOBAL · SERVICE ENQUIRIES
Share your requirements and preferred timing. ITVC will review your enquiry and discuss a suitable service scope.
Call for quotation: 0914 564 579
Ho Chi Minh City: 0859 553 986
Email: itvc.haiphong@itvc-global.com
Head office: 6th Floor, 22 Ly Tu Trong, Hong Bang Ward, Hai Phong, Vietnam.
Dịch vụ của chúng tôi
Tin tức & Sự kiện
Thư viện ảnh
Thư viện video
Copyright © 2014 ICTV. All Rights Reserved.
tư vấn iso, tu van iso, kiểm toán năng lượng, kiem toan nang luong